CRIUS V6

A high-end mechanical ventilator from Northern Meditec.

A wide range of standard features and options allows you to fit the Crius V6 to your needs.

Description

Electrial Interface
Nurse call, USB, NET, RS232, VGA

Interface Type
Main patient outlet:ISO 22M/15F
Oxygen inlet:DISS or NIST male

Display
Display size: 15.6 in diagonal, 18.5”optional
Display type: Active matrix color TFT LCD
Display resolution: SVGA resolution, 1366 x 768

Controls
Fully electronic control
Ventilation type: Blower
Ventilation modes:
A/C-VCV, A/C-PCV, A/C-PRVC, SIMV-VC, SIMV-PC, SIMV-PRVC, BIPAP, APRV, CPAP/PSV,
CPAP-VG, NIV, IV.
Special functions:
manual breath, O2 therapy, standby, screen-lock, inspiratory hold, expiratory hold, sigh,
ATC, RSB, Compliance, p0.1, calibrate, nebulizer, O2 suction.
Patient types: Adult/Pediatric/Neonate
Patient height: Adjustable

Monitoring
Real-time waveforms:
Paw, Flow, Volume, EtCO2, SPO2
Optional: CO2, SPO2 (related parameters)
Loops: P-V, V-Flow, Flow- P
Trends: 1s, 5s,1min,10min, 30min, 60min

Parameter range
Tidal volume: 5 to 2000mL (2 to 2000ml optional)
Rate: 1 to 100bpm
PEEP/CPAP: 0 to 50 cmH2O
Oxygen: 21 to 100%
I:E ratio: 1:10 to 4:1
Inspiratory time (TI): 0.2 to 5 s
Flow trigger: 0.2 to 15 l/min
Pressure trigger: -0.5 to -20cmH2O
Pressure control: 5 to 90 cmH2O

Pressure support: 0 to 90 cmH2O, added to PEEP/CPAP
Pressure ramp: 0 to 2s
Apnea absence: 10 to 30s
Expiratory trigger sensitivity (ETS):
OFF, 5 to 90 % of inspiratory peak flow
Peak flow Spontaneous: > 210 L/min

Electrical and gas supplies
Input voltage:
110 to 240V ~ ±10 %, 50 / 60 Hz AC or 24 VDC±10 %
Power consumption: 50 W typical
Protection class: Class I
Backup battery:
2 batteries(5200mAh each)/ hot swappable
Oxygen supply:
280 to 600 kPa (41 to 87 psi), 120 L / min
Low pressure:
oxygen ≤15 L / min, max. 600 hPa for low pressure

Alarms
Operator-adjustable:
Low/high minute volume, low/high pressure, low/high tidal volume, low/high rate, apnea time, low/high oxygenOptional: low/high CO2, low/high SPO2
Special alarms:
Oxygen concentration, disconnection, loss of PEEP, exhalation obstruction, flow sensor, power supply batteries, gassupply
Loudness Adjustable: 1 to 9
Event log: Storage and display of up to 1000 events with date and time stamp

Physical dimensions
Weight: < 45.3 kg
Main unit dimensions(WxHxD): Approx. 600x402x415mm

The ventilator is already integrated with expiratory volume monitor, pressure measurement device,
and pressure release device. It is equipped with alarm system, O2 monitor and CO2 monitor,
where:
◼ The expiratory volume monitor, pressure measurement device, and pressure release
devicecomply with ISO 80601-2-12.
◼ The alarm system complies with IEC 60601-1-8.

◼ The O2 monitor complies with ISO 80601-2-55.
◼ The CO2 monitor complies with ISO 80601-2-55.
◼ The gas supply hose assembly complies with ISO 5359.

 